{"product_id":"thermobile-bio-oil-fired-heater","title":"Thermobile Bio Oil Fired Heater","description":"\u003ch3\u003eThermobile Bio Oil Fired Heater\u003c\/h3\u003e\n\u003cp\u003e90.. Full combustion is achieved in a vaporising system and non-burnable residue is retained in the burner pan.\u003c\/p\u003e\n\u003cp\u003eStraightforward deployment and intuitive operation mean technicians can use the Thermobile Oil Fired Heater from day one without extended training. Built to commercial durability standards, it is designed to last through the pressures of a busy workshop.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSolvents\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThinners\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePetro-chemical based oils\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTransformer oil\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAny oil above S.A.E. 90\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectricity Supply 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFlue pipe installation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCombustion air supply\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAccess to built in fuel tank\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1 x T piece complete with Draught Stabiliser\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Btu\/hr (1) - Min (Energy B):\u003c\/strong\u003e 68,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Btu\/hr (1) - Min (Energy B Thermo):\u003c\/strong\u003e 68,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Btu\/hr (1) - Min (Energy 1):\u003c\/strong\u003e 68,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Btu\/hr (1) - Min (Energy 2):\u003c\/strong\u003e 85,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity Btu\/hr (1) - Min (Energy 3):\u003c\/strong\u003e 130,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Consumption L\/h (1) - Min (Energy B):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Consumption L\/h (1) - Min (Energy B Thermo):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Consumption L\/h (1) - Min (Energy 1):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Consumption L\/h (1) - Min (Energy 2):\u003c\/strong\u003e 2.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Consumption L\/h (1) - Min (Energy 3):\u003c\/strong\u003e 3.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank Capacity - Litres (Energy B):\u003c\/strong\u003e 50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank Capacity - Litres (Energy B Thermo):\u003c\/strong\u003e 50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank Capacity - Litres (Energy 1):\u003c\/strong\u003e 50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank Capacity - Litres (Energy 2):\u003c\/strong\u003e 55\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTank Capacity - Litres (Energy 3):\u003c\/strong\u003e 55\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight - Kg (Energy B):\u003c\/strong\u003e 67\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight - Kg (Energy B Thermo):\u003c\/strong\u003e 84\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight - Kg (Energy 1):\u003c\/strong\u003e 102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight - Kg (Energy 2):\u003c\/strong\u003e 135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight - Kg (Energy 3):\u003c\/strong\u003e 165\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent - A (Energy B):\u003c\/strong\u003e 0.23\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent - A (Energy B Thermo):\u003c\/strong\u003e 0.7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent - A (Energy 1):\u003c\/strong\u003e 0.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent - A (Energy 2):\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent - A (Energy 3):\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue Connection - mm (Energy B):\u003c\/strong\u003e 130\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue Connection - mm (Energy B Thermo):\u003c\/strong\u003e 130\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue Connection - mm (Energy 1):\u003c\/strong\u003e 130\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue Connection - mm (Energy 2):\u003c\/strong\u003e 130\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlue Connection - mm (Energy 3):\u003c\/strong\u003e 180\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Airflow - m3\/hr (Energy B Thermo):\u003c\/strong\u003e 1000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Airflow - m3\/hr (Energy 1):\u003c\/strong\u003e 1000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Airflow - m3\/hr (Energy 2):\u003c\/strong\u003e 3000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated Airflow - m3\/hr (Energy 3):\u003c\/strong\u003e 3000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Space to be Heated - cu.ft (Energy B):\u003c\/strong\u003e 20,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Space to be Heated - cu.ft (Energy B Thermo):\u003c\/strong\u003e 20,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Space to be Heated - cu.ft (Energy 1):\u003c\/strong\u003e 20,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Space to be Heated - cu.ft (Energy 2):\u003c\/strong\u003e 28,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Space to be Heated - cu.ft (Energy 3):\u003c\/strong\u003e 42,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth - cm (Energy B):\u003c\/strong\u003e 54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth - cm (Energy B Thermo):\u003c\/strong\u003e 54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth - cm (Energy 1):\u003c\/strong\u003e 54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth - cm (Energy 2):\u003c\/strong\u003e 82\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth - cm (Energy 3):\u003c\/strong\u003e 82\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth - cm (Energy B):\u003c\/strong\u003e 98\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth - cm (Energy B Thermo):\u003c\/strong\u003e 105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth - cm (Energy 1):\u003c\/strong\u003e 105\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth - cm (Energy 2):\u003c\/strong\u003e 110\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth - cm (Energy 3):\u003c\/strong\u003e 115\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight - cm (Energy B):\u003c\/strong\u003e 113\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight - cm (Energy B Thermo):\u003c\/strong\u003e 127\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight - cm (Energy 1):\u003c\/strong\u003e 127\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight - cm (Energy 2):\u003c\/strong\u003e 108\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight - cm (Energy 3):\u003c\/strong\u003e 128\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermobile","offers":[{"title":"Default Title","offer_id":53656273977685,"sku":"THERMBIOENERGYB","price":2670.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0976\/6204\/2453\/files\/bio-energy.png?v=1775818633","url":"https:\/\/advantagempire.co.uk\/products\/thermobile-bio-oil-fired-heater","provider":"Advantage Empire","version":"1.0","type":"link"}